Commit c2463b5bf4fa4fe8256190e9c211a0813a675f6e

Authored by José Maria Villac Pinheiro
1 parent 5305652e
Exists in master

Alterados nomes dos arquivos para retirar acentos e manter compatibilidade com Mac

db/SqlServer/03 - Criacao do Banco Importacao da Base de Dados SQL Server - A.doc 0 → 100644
No preview for this file type
db/SqlServer/03 - Criacao do Banco Importação da Base de Dados SQL Server - A.doc
No preview for this file type
db/SqlServer/20170824162400-Historico_modificacoes_banco_dados_geosan-v.7.4.0 - Copia.txt 0 → 100644
... ... @@ -0,0 +1,173 @@
  1 +USE [nome_do_banco_de_dados]
  2 +GO
  3 +
  4 +/****** Object: Table [dbo].[GS_NOS] Script Date: 08/24/2017 16:07:17 ******/
  5 +SET ANSI_NULLS ON
  6 +GO
  7 +
  8 +SET QUOTED_IDENTIFIER ON
  9 +GO
  10 +
  11 +SET ANSI_PADDING ON
  12 +GO
  13 +
  14 +CREATE TABLE [dbo].[GS_NOS](
  15 + [object_id_] [nvarchar](50) NOT NULL,
  16 + [idtipo] [int] NULL,
  17 + [idsubtipo] [int] NULL,
  18 + [valor] [varchar](50) NULL,
  19 + [estado] [int] NULL,
  20 + [localiza] [int] NULL,
  21 + [cota] [float] NULL,
  22 + [notacao] [nvarchar](50) NULL,
  23 + [demanda] [float] NULL,
  24 + [datainst] [varchar](50) NULL,
  25 + [descric] [varchar](25) NULL,
  26 + [especif] [varchar](50) NULL,
  27 + [x] [float] NULL,
  28 + [y] [float] NULL
  29 +) ON [PRIMARY]
  30 +
  31 +GO
  32 +
  33 +SET ANSI_PADDING OFF
  34 +GO
  35 +
  36 +USE [nome_do_banco_de_dados]
  37 +GO
  38 +
  39 +/****** Object: Table [dbo].[GS_REDES] Script Date: 08/24/2017 16:09:36 ******/
  40 +SET ANSI_NULLS ON
  41 +GO
  42 +
  43 +SET QUOTED_IDENTIFIER ON
  44 +GO
  45 +
  46 +SET ANSI_PADDING ON
  47 +GO
  48 +
  49 +CREATE TABLE [dbo].[GS_REDES](
  50 + [object_id_] [nvarchar](255) NOT NULL,
  51 + [idtipo] [int] NULL,
  52 + [tiporede] [varchar](25) NULL,
  53 + [especifi] [varchar](100) NULL,
  54 + [altinic] [float] NULL,
  55 + [altfinal] [float] NULL,
  56 + [profinic] [float] NULL,
  57 + [proffin] [float] NULL,
  58 + [diamint] [varchar](25) NULL,
  59 + [diamext] [varchar](25) NULL,
  60 + [noinic] [int] NULL,
  61 + [nofinal] [int] NULL,
  62 + [espessur] [float] NULL,
  63 + [material] [int] NULL,
  64 + [matnome] [nvarchar](50) NOT NULL,
  65 + [comprim] [float] NULL,
  66 + [compcalc] [float] NULL,
  67 + [forneced] [int] NULL,
  68 + [forempre] [nvarchar](40) NOT NULL,
  69 + [localiza] [int] NULL,
  70 + [locanome] [nvarchar](25) NOT NULL,
  71 + [estado] [int] NULL,
  72 + [estnome] [nvarchar](25) NOT NULL,
  73 + [validinf] [int] NULL,
  74 + [rugosid] [float] NOT NULL,
  75 + [setor] [float] NOT NULL,
  76 + [datainst] [varchar](25) NULL,
  77 + [ladorua] [smallint] NULL,
  78 + [ladodesc] [varchar](50) NOT NULL,
  79 + [distdiv] [numeric](18, 2) NULL,
  80 + [problema] [smallint] NULL,
  81 + [usuario] [varchar](50) NULL,
  82 + [datausu] [varchar](50) NULL,
  83 + [data] [varchar](25) NOT NULL,
  84 + [fabrican] [numeric](18, 0) NULL,
  85 + [fabrnome] [nvarchar](40) NOT NULL,
  86 + [LINE_ID] [int] NULL,
  87 + [txtacm] [varchar](50) NULL,
  88 + [txtab] [varchar](50) NULL,
  89 + [angulol] [float] NULL,
  90 + [txtabl1] [varchar](50) NULL,
  91 + [txtabl2] [varchar](50) NULL
  92 +) ON [PRIMARY]
  93 +
  94 +GO
  95 +
  96 +SET ANSI_PADDING OFF
  97 +GO
  98 +
  99 +USE [nome_do_banco_de_dados]
  100 +GO
  101 +
  102 +/****** Object: Table [dbo].[GS_RAMAIS] Script Date: 08/24/2017 16:10:44 ******/
  103 +SET ANSI_NULLS ON
  104 +GO
  105 +
  106 +SET QUOTED_IDENTIFIER ON
  107 +GO
  108 +
  109 +SET ANSI_PADDING ON
  110 +GO
  111 +
  112 +CREATE TABLE [dbo].[GS_RAMAIS](
  113 + [object_id_] [nvarchar](255) NULL,
  114 + [objidtre] [nvarchar](255) NULL,
  115 + [codlog] [int] NULL,
  116 + [distTest] [numeric](18, 2) NULL,
  117 + [distLado] [numeric](18, 2) NULL,
  118 + [compram] [numeric](18, 2) NULL,
  119 + [profram] [numeric](18, 2) NULL,
  120 + [poslote] [int] NULL,
  121 + [id] [int] NOT NULL,
  122 + [datalog] [varchar](30) NULL,
  123 + [usulog] [varchar](30) NULL
  124 +) ON [PRIMARY]
  125 +
  126 +GO
  127 +
  128 +SET ANSI_PADDING OFF
  129 +GO
  130 +
  131 +USE [nome_do_banco_de_dados]
  132 +GO
  133 +
  134 +/****** Object: Table [dbo].[GS_CONSUMIDORES] Script Date: 08/24/2017 16:12:58 ******/
  135 +SET ANSI_NULLS ON
  136 +GO
  137 +
  138 +SET QUOTED_IDENTIFIER ON
  139 +GO
  140 +
  141 +CREATE TABLE [dbo].[GS_CONSUMIDORES](
  142 + [OBJECT_ID_] [nvarchar](250) NULL,
  143 + [NRO_LIG] [nvarchar](50) NULL,
  144 + [NROL_SDV] [nvarchar](50) NULL,
  145 + [INSCLOTE] [nvarchar](50) NULL,
  146 + [AUTO] [nvarchar](10) NULL,
  147 + [CONS_LPS] [nvarchar](24) NULL,
  148 + [TIPO] [nvarchar](20) NULL,
  149 + [COD_LOG] [nvarchar](30) NULL,
  150 + [ENDERECO] [nvarchar](250) NULL,
  151 + [NUM_CASA] [nvarchar](15) NULL,
  152 + [COMPLLOG] [nvarchar](60) NULL,
  153 + [BAIRRO] [nvarchar](150) NULL,
  154 + [HIDROM] [nvarchar](30) NULL,
  155 + [COD_CONS] [nvarchar](11) NULL,
  156 + [CODCONSDV] [nvarchar](11) NULL,
  157 + [CONSUM] [nvarchar](150) NULL,
  158 + [TEL_RES] [nvarchar](20) NULL,
  159 + [TEL_COM] [nvarchar](20) NULL,
  160 + [ECONOM] [nvarchar](10) NULL,
  161 + [DATAIMP] [nvarchar](30) NULL,
  162 + [DATAIMPE] [nvarchar](30) NULL,
  163 + [ROTALEIT] [nvarchar](50) NULL,
  164 + [GRUPOL] [nvarchar](10) NULL,
  165 + [ROTLEIT] [nvarchar](10) NULL,
  166 + [SEQLEI] [nvarchar](10) NULL,
  167 + [CONSFAT] [nvarchar](15) NULL,
  168 + [CONMED] [nvarchar](15) NULL,
  169 + [MES] [nvarchar](2) NULL,
  170 + [ANO] [nvarchar](2) NULL
  171 +) ON [PRIMARY]
  172 +
  173 +GO
0 174 \ No newline at end of file
... ...
db/SqlServer/20170824162400-Historico_modificacoes_banco_dados_geosan-v.7.4.0 - Cópia.txt
... ... @@ -1,173 +0,0 @@
1   -USE [nome_do_banco_de_dados]
2   -GO
3   -
4   -/****** Object: Table [dbo].[GS_NOS] Script Date: 08/24/2017 16:07:17 ******/
5   -SET ANSI_NULLS ON
6   -GO
7   -
8   -SET QUOTED_IDENTIFIER ON
9   -GO
10   -
11   -SET ANSI_PADDING ON
12   -GO
13   -
14   -CREATE TABLE [dbo].[GS_NOS](
15   - [object_id_] [nvarchar](50) NOT NULL,
16   - [idtipo] [int] NULL,
17   - [idsubtipo] [int] NULL,
18   - [valor] [varchar](50) NULL,
19   - [estado] [int] NULL,
20   - [localiza] [int] NULL,
21   - [cota] [float] NULL,
22   - [notacao] [nvarchar](50) NULL,
23   - [demanda] [float] NULL,
24   - [datainst] [varchar](50) NULL,
25   - [descric] [varchar](25) NULL,
26   - [especif] [varchar](50) NULL,
27   - [x] [float] NULL,
28   - [y] [float] NULL
29   -) ON [PRIMARY]
30   -
31   -GO
32   -
33   -SET ANSI_PADDING OFF
34   -GO
35   -
36   -USE [nome_do_banco_de_dados]
37   -GO
38   -
39   -/****** Object: Table [dbo].[GS_REDES] Script Date: 08/24/2017 16:09:36 ******/
40   -SET ANSI_NULLS ON
41   -GO
42   -
43   -SET QUOTED_IDENTIFIER ON
44   -GO
45   -
46   -SET ANSI_PADDING ON
47   -GO
48   -
49   -CREATE TABLE [dbo].[GS_REDES](
50   - [object_id_] [nvarchar](255) NOT NULL,
51   - [idtipo] [int] NULL,
52   - [tiporede] [varchar](25) NULL,
53   - [especifi] [varchar](100) NULL,
54   - [altinic] [float] NULL,
55   - [altfinal] [float] NULL,
56   - [profinic] [float] NULL,
57   - [proffin] [float] NULL,
58   - [diamint] [varchar](25) NULL,
59   - [diamext] [varchar](25) NULL,
60   - [noinic] [int] NULL,
61   - [nofinal] [int] NULL,
62   - [espessur] [float] NULL,
63   - [material] [int] NULL,
64   - [matnome] [nvarchar](50) NOT NULL,
65   - [comprim] [float] NULL,
66   - [compcalc] [float] NULL,
67   - [forneced] [int] NULL,
68   - [forempre] [nvarchar](40) NOT NULL,
69   - [localiza] [int] NULL,
70   - [locanome] [nvarchar](25) NOT NULL,
71   - [estado] [int] NULL,
72   - [estnome] [nvarchar](25) NOT NULL,
73   - [validinf] [int] NULL,
74   - [rugosid] [float] NOT NULL,
75   - [setor] [float] NOT NULL,
76   - [datainst] [varchar](25) NULL,
77   - [ladorua] [smallint] NULL,
78   - [ladodesc] [varchar](50) NOT NULL,
79   - [distdiv] [numeric](18, 2) NULL,
80   - [problema] [smallint] NULL,
81   - [usuario] [varchar](50) NULL,
82   - [datausu] [varchar](50) NULL,
83   - [data] [varchar](25) NOT NULL,
84   - [fabrican] [numeric](18, 0) NULL,
85   - [fabrnome] [nvarchar](40) NOT NULL,
86   - [LINE_ID] [int] NULL,
87   - [txtacm] [varchar](50) NULL,
88   - [txtab] [varchar](50) NULL,
89   - [angulol] [float] NULL,
90   - [txtabl1] [varchar](50) NULL,
91   - [txtabl2] [varchar](50) NULL
92   -) ON [PRIMARY]
93   -
94   -GO
95   -
96   -SET ANSI_PADDING OFF
97   -GO
98   -
99   -USE [nome_do_banco_de_dados]
100   -GO
101   -
102   -/****** Object: Table [dbo].[GS_RAMAIS] Script Date: 08/24/2017 16:10:44 ******/
103   -SET ANSI_NULLS ON
104   -GO
105   -
106   -SET QUOTED_IDENTIFIER ON
107   -GO
108   -
109   -SET ANSI_PADDING ON
110   -GO
111   -
112   -CREATE TABLE [dbo].[GS_RAMAIS](
113   - [object_id_] [nvarchar](255) NULL,
114   - [objidtre] [nvarchar](255) NULL,
115   - [codlog] [int] NULL,
116   - [distTest] [numeric](18, 2) NULL,
117   - [distLado] [numeric](18, 2) NULL,
118   - [compram] [numeric](18, 2) NULL,
119   - [profram] [numeric](18, 2) NULL,
120   - [poslote] [int] NULL,
121   - [id] [int] NOT NULL,
122   - [datalog] [varchar](30) NULL,
123   - [usulog] [varchar](30) NULL
124   -) ON [PRIMARY]
125   -
126   -GO
127   -
128   -SET ANSI_PADDING OFF
129   -GO
130   -
131   -USE [nome_do_banco_de_dados]
132   -GO
133   -
134   -/****** Object: Table [dbo].[GS_CONSUMIDORES] Script Date: 08/24/2017 16:12:58 ******/
135   -SET ANSI_NULLS ON
136   -GO
137   -
138   -SET QUOTED_IDENTIFIER ON
139   -GO
140   -
141   -CREATE TABLE [dbo].[GS_CONSUMIDORES](
142   - [OBJECT_ID_] [nvarchar](250) NULL,
143   - [NRO_LIG] [nvarchar](50) NULL,
144   - [NROL_SDV] [nvarchar](50) NULL,
145   - [INSCLOTE] [nvarchar](50) NULL,
146   - [AUTO] [nvarchar](10) NULL,
147   - [CONS_LPS] [nvarchar](24) NULL,
148   - [TIPO] [nvarchar](20) NULL,
149   - [COD_LOG] [nvarchar](30) NULL,
150   - [ENDERECO] [nvarchar](250) NULL,
151   - [NUM_CASA] [nvarchar](15) NULL,
152   - [COMPLLOG] [nvarchar](60) NULL,
153   - [BAIRRO] [nvarchar](150) NULL,
154   - [HIDROM] [nvarchar](30) NULL,
155   - [COD_CONS] [nvarchar](11) NULL,
156   - [CODCONSDV] [nvarchar](11) NULL,
157   - [CONSUM] [nvarchar](150) NULL,
158   - [TEL_RES] [nvarchar](20) NULL,
159   - [TEL_COM] [nvarchar](20) NULL,
160   - [ECONOM] [nvarchar](10) NULL,
161   - [DATAIMP] [nvarchar](30) NULL,
162   - [DATAIMPE] [nvarchar](30) NULL,
163   - [ROTALEIT] [nvarchar](50) NULL,
164   - [GRUPOL] [nvarchar](10) NULL,
165   - [ROTLEIT] [nvarchar](10) NULL,
166   - [SEQLEI] [nvarchar](10) NULL,
167   - [CONSFAT] [nvarchar](15) NULL,
168   - [CONMED] [nvarchar](15) NULL,
169   - [MES] [nvarchar](2) NULL,
170   - [ANO] [nvarchar](2) NULL
171   -) ON [PRIMARY]
172   -
173   -GO
174 0 \ No newline at end of file
sql/20151126132800-querie para inserir novos parametros.sql 0 → 100644
... ... @@ -0,0 +1,95 @@
  1 +USE [ArturNogueira-B]
  2 +
  3 +
  4 +/* insere parâmetros de bomba */
  5 +
  6 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  7 +(3, 1, 'POTÊNCIA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  8 +
  9 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  10 +(3, 2, 'CARGA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  11 +
  12 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  13 +(3, 3, 'VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  14 +
  15 +/* insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  16 +(3, 4, 'REND_VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL) */
  17 +
  18 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  19 +(3, 4, 'RENDIMENTO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  20 +
  21 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  22 +(3, 5, 'CURVA DA BOMBA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  23 +
  24 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  25 +(3, 6, 'CURVA DE REND', 'False', 0.0000, 0.0000, 0, 2, NULL)
  26 +
  27 +
  28 +/* Apaga todos os metadados de bomba */
  29 +
  30 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 1 and Description_ = 'POTÊNCIA'
  31 +
  32 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 2 and Description_ = 'CARGA'
  33 +
  34 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 3 and Description_ = 'VAZÃO'
  35 +
  36 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 4 and Description_ = 'RENDIMENTO'
  37 +
  38 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 5 and Description_ = 'CURVA DA BOMBA'
  39 +
  40 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 6 and Description_ = 'CURVA DE REND'
  41 +
  42 +/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
  43 +
  44 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 1
  45 +
  46 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 2
  47 +
  48 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 3
  49 +
  50 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 4
  51 +
  52 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 5
  53 +
  54 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 6
  55 +
  56 +/* insere parâmetros de um RNV */
  57 +
  58 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  59 +(28, 1, 'ALT INICIAL', 'False', 0.0000, 0.0000, 0, 2, NULL)
  60 +
  61 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  62 +(28, 2, 'ALT MIN', 'False', 0.0000, 0.0000, 0, 2, NULL)
  63 +
  64 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  65 +(28, 3, 'ALT MAX', 'False', 0.0000, 0.0000, 0, 2, NULL)
  66 +
  67 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  68 +(28, 4, 'DIÂMETRO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  69 +
  70 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  71 +(28, 5, 'CURVA DE VOLUME', 'False', 0.0000, 0.0000, 0, 2, NULL)
  72 +
  73 +/* Apaga todos os metadados de RNV */
  74 +
  75 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 1 and Description_ = 'ALT INICIAL'
  76 +
  77 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 2 and Description_ = 'ALT MIN'
  78 +
  79 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 3 and Description_ = 'ALT MAX'
  80 +
  81 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'DIÂMETRO'
  82 +
  83 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'CURVA DE VOLUME'
  84 +
  85 +/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
  86 +
  87 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 1
  88 +
  89 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 2
  90 +
  91 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 3
  92 +
  93 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 4
  94 +
  95 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 5
0 96 \ No newline at end of file
... ...
sql/20151126132800-querie para inserir novos parâmetros.sql
... ... @@ -1,95 +0,0 @@
1   -USE [ArturNogueira-B]
2   -
3   -
4   -/* insere parâmetros de bomba */
5   -
6   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
7   -(3, 1, 'POTÊNCIA', 'False', 0.0000, 0.0000, 0, 2, NULL)
8   -
9   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
10   -(3, 2, 'CARGA', 'False', 0.0000, 0.0000, 0, 2, NULL)
11   -
12   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
13   -(3, 3, 'VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL)
14   -
15   -/* insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
16   -(3, 4, 'REND_VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL) */
17   -
18   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
19   -(3, 4, 'RENDIMENTO', 'False', 0.0000, 0.0000, 0, 2, NULL)
20   -
21   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
22   -(3, 5, 'CURVA DA BOMBA', 'False', 0.0000, 0.0000, 0, 2, NULL)
23   -
24   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
25   -(3, 6, 'CURVA DE REND', 'False', 0.0000, 0.0000, 0, 2, NULL)
26   -
27   -
28   -/* Apaga todos os metadados de bomba */
29   -
30   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 1 and Description_ = 'POTÊNCIA'
31   -
32   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 2 and Description_ = 'CARGA'
33   -
34   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 3 and Description_ = 'VAZÃO'
35   -
36   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 4 and Description_ = 'RENDIMENTO'
37   -
38   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 5 and Description_ = 'CURVA DA BOMBA'
39   -
40   -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 6 and Description_ = 'CURVA DE REND'
41   -
42   -/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
43   -
44   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 1
45   -
46   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 2
47   -
48   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 3
49   -
50   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 4
51   -
52   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 5
53   -
54   -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 6
55   -
56   -/* insere parâmetros de um RNV */
57   -
58   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
59   -(28, 1, 'ALT INICIAL', 'False', 0.0000, 0.0000, 0, 2, NULL)
60   -
61   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
62   -(28, 2, 'ALT MIN', 'False', 0.0000, 0.0000, 0, 2, NULL)
63   -
64   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
65   -(28, 3, 'ALT MAX', 'False', 0.0000, 0.0000, 0, 2, NULL)
66   -
67   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
68   -(28, 4, 'DIÂMETRO', 'False', 0.0000, 0.0000, 0, 2, NULL)
69   -
70   -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
71   -(28, 5, 'CURVA DE VOLUME', 'False', 0.0000, 0.0000, 0, 2, NULL)
72   -
73   -/* Apaga todos os metadados de RNV */
74   -
75   -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 1 and Description_ = 'ALT INICIAL'
76   -
77   -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 2 and Description_ = 'ALT MIN'
78   -
79   -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 3 and Description_ = 'ALT MAX'
80   -
81   -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'DIÂMETRO'
82   -
83   -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'CURVA DE VOLUME'
84   -
85   -/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
86   -
87   -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 1
88   -
89   -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 2
90   -
91   -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 3
92   -
93   -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 4
94   -
95   -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 5
96 0 \ No newline at end of file
sql/20160209175500-GeoSan 7.0.43 - parametros novos para exportacao para EPANET.sql 0 → 100644
... ... @@ -0,0 +1,198 @@
  1 +/* Para criar as tabelas */
  2 +
  3 +USE [ArturNogueira-B]
  4 +
  5 +SET ANSI_NULLS ON
  6 +GO
  7 +SET QUOTED_IDENTIFIER ON
  8 +GO
  9 +SET ANSI_PADDING ON
  10 +GO
  11 +CREATE TABLE XXXX
  12 +GO
  13 +SET ANSI_PADDING OFF
  14 +GO
  15 +
  16 +
  17 +/* insere os tipos de componentes os quais um nó pode vir a ser */
  18 +
  19 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
  20 +
  21 +CREATE TABLE [dbo].[WaterComponentsTypes](
  22 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  23 + [Description_] [varchar](25) NULL,
  24 + [Specification_] [varchar](100) NULL
  25 +) ON [PRIMARY]
  26 +
  27 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  63 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  64 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  65 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  66 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  67 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  68 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  69 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  70 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  71 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  72 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  73 +
  74 +
  75 +/* Apaga todos os metadados dos nós */
  76 +
  77 +delete from WaterComponentsTypes where id_Type = 0
  78 +delete from WaterComponentsTypes where id_Type = 1
  79 +delete from WaterComponentsTypes where id_Type = 2
  80 +delete from WaterComponentsTypes where id_Type = 3
  81 +delete from WaterComponentsTypes where id_Type = 4
  82 +delete from WaterComponentsTypes where id_Type = 5
  83 +delete from WaterComponentsTypes where id_Type = 6
  84 +delete from WaterComponentsTypes where id_Type = 7
  85 +delete from WaterComponentsTypes where id_Type = 8
  86 +delete from WaterComponentsTypes where id_Type = 9
  87 +delete from WaterComponentsTypes where id_Type = 10
  88 +delete from WaterComponentsTypes where id_Type = 11
  89 +delete from WaterComponentsTypes where id_Type = 12
  90 +delete from WaterComponentsTypes where id_Type = 13
  91 +delete from WaterComponentsTypes where id_Type = 14
  92 +delete from WaterComponentsTypes where id_Type = 15
  93 +delete from WaterComponentsTypes where id_Type = 16
  94 +delete from WaterComponentsTypes where id_Type = 17
  95 +delete from WaterComponentsTypes where id_Type = 17
  96 +delete from WaterComponentsTypes where id_Type = 19
  97 +delete from WaterComponentsTypes where id_Type = 20
  98 +delete from WaterComponentsTypes where id_Type = 21
  99 +delete from WaterComponentsTypes where id_Type = 22
  100 +delete from WaterComponentsTypes where id_Type = 23
  101 +delete from WaterComponentsTypes where id_Type = 24
  102 +delete from WaterComponentsTypes where id_Type = 25
  103 +delete from WaterComponentsTypes where id_Type = 26
  104 +delete from WaterComponentsTypes where id_Type = 27
  105 +delete from WaterComponentsTypes where id_Type = 28
  106 +delete from WaterComponentsTypes where id_Type = 29
  107 +delete from WaterComponentsTypes where id_Type = 30
  108 +delete from WaterComponentsTypes where id_Type = 31
  109 +delete from WaterComponentsTypes where id_Type = 32
  110 +delete from WaterComponentsTypes where id_Type = 33
  111 +delete from WaterComponentsTypes where id_Type = 34
  112 +delete from WaterComponentsTypes where id_Type = 35
  113 +delete from WaterComponentsTypes where id_Type = 36
  114 +delete from WaterComponentsTypes where id_Type = 37
  115 +delete from WaterComponentsTypes where id_Type = 38
  116 +delete from WaterComponentsTypes where id_Type = 39
  117 +delete from WaterComponentsTypes where id_Type = 40
  118 +delete from WaterComponentsTypes where id_Type = 41
  119 +delete from WaterComponentsTypes where id_Type = 42
  120 +delete from WaterComponentsTypes where id_Type = 43
  121 +delete from WaterComponentsTypes where id_Type = 44
  122 +delete from WaterComponentsTypes where id_Type = 45
  123 +delete from WaterComponentsTypes where id_Type = 46
  124 +
  125 +/* insere parâmetros de todos subtipos */
  126 +
  127 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  128 + [id_Type] [int] NOT NULL,
  129 + [id_SubType] [int] NOT NULL,
  130 + [Description_] [varchar](50) NULL,
  131 + [Selection_] [bit] NOT NULL,
  132 + [Max_] [numeric](18, 4) NULL,
  133 + [Min_] [numeric](18, 4) NULL,
  134 + [DefaultValue] [nvarchar](50) NOT NULL,
  135 + [DataType] [int] NULL,
  136 + [EPAREF] [nvarchar](10) NULL
  137 +) ON [PRIMARY]
  138 +
  139 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  140 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  141 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  142 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  143 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  144 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  145 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  146 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  147 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  148 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  149 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  150 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  151 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  152 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  153 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  154 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  155 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  156 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  157 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  158 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  159 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  160 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  161 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  162 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  163 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  164 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  165 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  166 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  167 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  168 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  169 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  170 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  171 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  172 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  173 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  174 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  175 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  176 +
  177 +/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
  178 +
  179 +CREATE TABLE [dbo].[WaterComponentsSelections](
  180 + [id_Type] [int] NOT NULL,
  181 + [id_SubType] [int] NOT NULL,
  182 + [Option_] [varchar](25) NOT NULL,
  183 + [Value_] [nvarchar](50) NOT NULL,
  184 + [Description_] [varchar](30) NULL
  185 +) ON [PRIMARY]
  186 +
  187 +GO
  188 +
  189 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  190 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  191 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  192 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  193 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  194 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  195 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  196 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  197 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
  198 +
... ...
sql/20160209175500-GeoSan 7.0.43 - parâmetros novos para exportação para EPANET.sql
... ... @@ -1,198 +0,0 @@
1   -/* Para criar as tabelas */
2   -
3   -USE [ArturNogueira-B]
4   -
5   -SET ANSI_NULLS ON
6   -GO
7   -SET QUOTED_IDENTIFIER ON
8   -GO
9   -SET ANSI_PADDING ON
10   -GO
11   -CREATE TABLE XXXX
12   -GO
13   -SET ANSI_PADDING OFF
14   -GO
15   -
16   -
17   -/* insere os tipos de componentes os quais um nó pode vir a ser */
18   -
19   -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
20   -
21   -CREATE TABLE [dbo].[WaterComponentsTypes](
22   - [id_Type] [int] IDENTITY(1,1) NOT NULL,
23   - [Description_] [varchar](25) NULL,
24   - [Specification_] [varchar](100) NULL
25   -) ON [PRIMARY]
26   -
27   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
28   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
29   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
30   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
31   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
32   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
33   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
34   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
35   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
36   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
37   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
38   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
39   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
40   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
41   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
42   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
43   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
44   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
45   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
46   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
47   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
48   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
49   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
50   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
51   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
52   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
53   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
54   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
55   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
56   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
57   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
58   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
59   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
60   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
61   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
62   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
63   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
64   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
65   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
66   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
67   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
68   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
69   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
70   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
71   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
72   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
73   -
74   -
75   -/* Apaga todos os metadados dos nós */
76   -
77   -delete from WaterComponentsTypes where id_Type = 0
78   -delete from WaterComponentsTypes where id_Type = 1
79   -delete from WaterComponentsTypes where id_Type = 2
80   -delete from WaterComponentsTypes where id_Type = 3
81   -delete from WaterComponentsTypes where id_Type = 4
82   -delete from WaterComponentsTypes where id_Type = 5
83   -delete from WaterComponentsTypes where id_Type = 6
84   -delete from WaterComponentsTypes where id_Type = 7
85   -delete from WaterComponentsTypes where id_Type = 8
86   -delete from WaterComponentsTypes where id_Type = 9
87   -delete from WaterComponentsTypes where id_Type = 10
88   -delete from WaterComponentsTypes where id_Type = 11
89   -delete from WaterComponentsTypes where id_Type = 12
90   -delete from WaterComponentsTypes where id_Type = 13
91   -delete from WaterComponentsTypes where id_Type = 14
92   -delete from WaterComponentsTypes where id_Type = 15
93   -delete from WaterComponentsTypes where id_Type = 16
94   -delete from WaterComponentsTypes where id_Type = 17
95   -delete from WaterComponentsTypes where id_Type = 17
96   -delete from WaterComponentsTypes where id_Type = 19
97   -delete from WaterComponentsTypes where id_Type = 20
98   -delete from WaterComponentsTypes where id_Type = 21
99   -delete from WaterComponentsTypes where id_Type = 22
100   -delete from WaterComponentsTypes where id_Type = 23
101   -delete from WaterComponentsTypes where id_Type = 24
102   -delete from WaterComponentsTypes where id_Type = 25
103   -delete from WaterComponentsTypes where id_Type = 26
104   -delete from WaterComponentsTypes where id_Type = 27
105   -delete from WaterComponentsTypes where id_Type = 28
106   -delete from WaterComponentsTypes where id_Type = 29
107   -delete from WaterComponentsTypes where id_Type = 30
108   -delete from WaterComponentsTypes where id_Type = 31
109   -delete from WaterComponentsTypes where id_Type = 32
110   -delete from WaterComponentsTypes where id_Type = 33
111   -delete from WaterComponentsTypes where id_Type = 34
112   -delete from WaterComponentsTypes where id_Type = 35
113   -delete from WaterComponentsTypes where id_Type = 36
114   -delete from WaterComponentsTypes where id_Type = 37
115   -delete from WaterComponentsTypes where id_Type = 38
116   -delete from WaterComponentsTypes where id_Type = 39
117   -delete from WaterComponentsTypes where id_Type = 40
118   -delete from WaterComponentsTypes where id_Type = 41
119   -delete from WaterComponentsTypes where id_Type = 42
120   -delete from WaterComponentsTypes where id_Type = 43
121   -delete from WaterComponentsTypes where id_Type = 44
122   -delete from WaterComponentsTypes where id_Type = 45
123   -delete from WaterComponentsTypes where id_Type = 46
124   -
125   -/* insere parâmetros de todos subtipos */
126   -
127   -CREATE TABLE [dbo].[WaterComponentsSubTypes](
128   - [id_Type] [int] NOT NULL,
129   - [id_SubType] [int] NOT NULL,
130   - [Description_] [varchar](50) NULL,
131   - [Selection_] [bit] NOT NULL,
132   - [Max_] [numeric](18, 4) NULL,
133   - [Min_] [numeric](18, 4) NULL,
134   - [DefaultValue] [nvarchar](50) NOT NULL,
135   - [DataType] [int] NULL,
136   - [EPAREF] [nvarchar](10) NULL
137   -) ON [PRIMARY]
138   -
139   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
140   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
141   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
142   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
143   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
144   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
145   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
146   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
147   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
148   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
149   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
150   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
151   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
152   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
153   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
154   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
155   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
156   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
157   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
158   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
159   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
160   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
161   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
162   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
163   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
164   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
165   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
166   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
167   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
168   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
169   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
170   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
171   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
172   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
173   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
174   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
175   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
176   -
177   -/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
178   -
179   -CREATE TABLE [dbo].[WaterComponentsSelections](
180   - [id_Type] [int] NOT NULL,
181   - [id_SubType] [int] NOT NULL,
182   - [Option_] [varchar](25) NOT NULL,
183   - [Value_] [nvarchar](50) NOT NULL,
184   - [Description_] [varchar](30) NULL
185   -) ON [PRIMARY]
186   -
187   -GO
188   -
189   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
190   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
191   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
192   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
193   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
194   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
195   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
196   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
197   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
198   -
sql/20160210081600-GeoSan 7.0.43 - parametros para adicionar para banco 7.0.31.sql 0 → 100644
... ... @@ -0,0 +1,201 @@
  1 +/* Queries para os usuários que possuem a versão do banco 7.0.31 e desejem somente atualizar os metadados para rodar a versão 7.0.43 *?
  2 +
  3 +
  4 +/* Para criar as tabelas */
  5 +
  6 +USE [ArturNogueira-B]
  7 +
  8 +SET ANSI_NULLS ON
  9 +GO
  10 +SET QUOTED_IDENTIFIER ON
  11 +GO
  12 +SET ANSI_PADDING ON
  13 +GO
  14 +CREATE TABLE XXXX
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +
  19 +
  20 +/* insere os tipos de componentes os quais um nó pode vir a ser */
  21 +
  22 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
  23 +
  24 +CREATE TABLE [dbo].[WaterComponentsTypes](
  25 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  26 + [Description_] [varchar](25) NULL,
  27 + [Specification_] [varchar](100) NULL
  28 +) ON [PRIMARY]
  29 +
  30 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  63 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  64 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  65 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  66 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  67 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  68 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  69 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  70 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  71 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  72 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  73 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  74 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  75 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  76 +
  77 +
  78 +/* Apaga todos os metadados dos nós */
  79 +
  80 +delete from WaterComponentsTypes where id_Type = 0
  81 +delete from WaterComponentsTypes where id_Type = 1
  82 +delete from WaterComponentsTypes where id_Type = 2
  83 +delete from WaterComponentsTypes where id_Type = 3
  84 +delete from WaterComponentsTypes where id_Type = 4
  85 +delete from WaterComponentsTypes where id_Type = 5
  86 +delete from WaterComponentsTypes where id_Type = 6
  87 +delete from WaterComponentsTypes where id_Type = 7
  88 +delete from WaterComponentsTypes where id_Type = 8
  89 +delete from WaterComponentsTypes where id_Type = 9
  90 +delete from WaterComponentsTypes where id_Type = 10
  91 +delete from WaterComponentsTypes where id_Type = 11
  92 +delete from WaterComponentsTypes where id_Type = 12
  93 +delete from WaterComponentsTypes where id_Type = 13
  94 +delete from WaterComponentsTypes where id_Type = 14
  95 +delete from WaterComponentsTypes where id_Type = 15
  96 +delete from WaterComponentsTypes where id_Type = 16
  97 +delete from WaterComponentsTypes where id_Type = 17
  98 +delete from WaterComponentsTypes where id_Type = 17
  99 +delete from WaterComponentsTypes where id_Type = 19
  100 +delete from WaterComponentsTypes where id_Type = 20
  101 +delete from WaterComponentsTypes where id_Type = 21
  102 +delete from WaterComponentsTypes where id_Type = 22
  103 +delete from WaterComponentsTypes where id_Type = 23
  104 +delete from WaterComponentsTypes where id_Type = 24
  105 +delete from WaterComponentsTypes where id_Type = 25
  106 +delete from WaterComponentsTypes where id_Type = 26
  107 +delete from WaterComponentsTypes where id_Type = 27
  108 +delete from WaterComponentsTypes where id_Type = 28
  109 +delete from WaterComponentsTypes where id_Type = 29
  110 +delete from WaterComponentsTypes where id_Type = 30
  111 +delete from WaterComponentsTypes where id_Type = 31
  112 +delete from WaterComponentsTypes where id_Type = 32
  113 +delete from WaterComponentsTypes where id_Type = 33
  114 +delete from WaterComponentsTypes where id_Type = 34
  115 +delete from WaterComponentsTypes where id_Type = 35
  116 +delete from WaterComponentsTypes where id_Type = 36
  117 +delete from WaterComponentsTypes where id_Type = 37
  118 +delete from WaterComponentsTypes where id_Type = 38
  119 +delete from WaterComponentsTypes where id_Type = 39
  120 +delete from WaterComponentsTypes where id_Type = 40
  121 +delete from WaterComponentsTypes where id_Type = 41
  122 +delete from WaterComponentsTypes where id_Type = 42
  123 +delete from WaterComponentsTypes where id_Type = 43
  124 +delete from WaterComponentsTypes where id_Type = 44
  125 +delete from WaterComponentsTypes where id_Type = 45
  126 +delete from WaterComponentsTypes where id_Type = 46
  127 +
  128 +/* insere parâmetros de todos subtipos */
  129 +
  130 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  131 + [id_Type] [int] NOT NULL,
  132 + [id_SubType] [int] NOT NULL,
  133 + [Description_] [varchar](50) NULL,
  134 + [Selection_] [bit] NOT NULL,
  135 + [Max_] [numeric](18, 4) NULL,
  136 + [Min_] [numeric](18, 4) NULL,
  137 + [DefaultValue] [nvarchar](50) NOT NULL,
  138 + [DataType] [int] NULL,
  139 + [EPAREF] [nvarchar](10) NULL
  140 +) ON [PRIMARY]
  141 +
  142 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  143 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  144 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  145 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  146 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  147 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  148 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  149 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  150 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  151 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  152 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  153 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  154 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  155 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  156 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  157 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  158 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  159 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  160 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  161 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  162 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  163 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  164 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  165 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  166 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  167 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  168 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  169 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  170 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  171 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  172 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  173 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  174 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  175 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  176 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  177 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  178 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  179 +
  180 +/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
  181 +
  182 +CREATE TABLE [dbo].[WaterComponentsSelections](
  183 + [id_Type] [int] NOT NULL,
  184 + [id_SubType] [int] NOT NULL,
  185 + [Option_] [varchar](25) NOT NULL,
  186 + [Value_] [nvarchar](50) NOT NULL,
  187 + [Description_] [varchar](30) NULL
  188 +) ON [PRIMARY]
  189 +
  190 +GO
  191 +
  192 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  193 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  194 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  195 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  196 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  197 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  198 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  199 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  200 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
  201 +
... ...
sql/20160210081600-GeoSan 7.0.43 - parâmetros para adicionar para banco 7.0.31.sql
... ... @@ -1,201 +0,0 @@
1   -/* Queries para os usuários que possuem a versão do banco 7.0.31 e desejem somente atualizar os metadados para rodar a versão 7.0.43 *?
2   -
3   -
4   -/* Para criar as tabelas */
5   -
6   -USE [ArturNogueira-B]
7   -
8   -SET ANSI_NULLS ON
9   -GO
10   -SET QUOTED_IDENTIFIER ON
11   -GO
12   -SET ANSI_PADDING ON
13   -GO
14   -CREATE TABLE XXXX
15   -GO
16   -SET ANSI_PADDING OFF
17   -GO
18   -
19   -
20   -/* insere os tipos de componentes os quais um nó pode vir a ser */
21   -
22   -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
23   -
24   -CREATE TABLE [dbo].[WaterComponentsTypes](
25   - [id_Type] [int] IDENTITY(1,1) NOT NULL,
26   - [Description_] [varchar](25) NULL,
27   - [Specification_] [varchar](100) NULL
28   -) ON [PRIMARY]
29   -
30   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
31   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
32   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
33   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
34   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
35   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
36   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
37   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
38   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
39   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
40   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
41   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
42   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
43   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
44   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
45   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
46   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
47   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
48   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
49   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
50   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
51   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
52   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
53   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
54   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
55   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
56   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
57   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
58   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
59   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
60   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
61   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
62   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
63   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
64   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
65   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
66   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
67   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
68   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
69   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
70   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
71   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
72   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
73   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
74   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
75   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
76   -
77   -
78   -/* Apaga todos os metadados dos nós */
79   -
80   -delete from WaterComponentsTypes where id_Type = 0
81   -delete from WaterComponentsTypes where id_Type = 1
82   -delete from WaterComponentsTypes where id_Type = 2
83   -delete from WaterComponentsTypes where id_Type = 3
84   -delete from WaterComponentsTypes where id_Type = 4
85   -delete from WaterComponentsTypes where id_Type = 5
86   -delete from WaterComponentsTypes where id_Type = 6
87   -delete from WaterComponentsTypes where id_Type = 7
88   -delete from WaterComponentsTypes where id_Type = 8
89   -delete from WaterComponentsTypes where id_Type = 9
90   -delete from WaterComponentsTypes where id_Type = 10
91   -delete from WaterComponentsTypes where id_Type = 11
92   -delete from WaterComponentsTypes where id_Type = 12
93   -delete from WaterComponentsTypes where id_Type = 13
94   -delete from WaterComponentsTypes where id_Type = 14
95   -delete from WaterComponentsTypes where id_Type = 15
96   -delete from WaterComponentsTypes where id_Type = 16
97   -delete from WaterComponentsTypes where id_Type = 17
98   -delete from WaterComponentsTypes where id_Type = 17
99   -delete from WaterComponentsTypes where id_Type = 19
100   -delete from WaterComponentsTypes where id_Type = 20
101   -delete from WaterComponentsTypes where id_Type = 21
102   -delete from WaterComponentsTypes where id_Type = 22
103   -delete from WaterComponentsTypes where id_Type = 23
104   -delete from WaterComponentsTypes where id_Type = 24
105   -delete from WaterComponentsTypes where id_Type = 25
106   -delete from WaterComponentsTypes where id_Type = 26
107   -delete from WaterComponentsTypes where id_Type = 27
108   -delete from WaterComponentsTypes where id_Type = 28
109   -delete from WaterComponentsTypes where id_Type = 29
110   -delete from WaterComponentsTypes where id_Type = 30
111   -delete from WaterComponentsTypes where id_Type = 31
112   -delete from WaterComponentsTypes where id_Type = 32
113   -delete from WaterComponentsTypes where id_Type = 33
114   -delete from WaterComponentsTypes where id_Type = 34
115   -delete from WaterComponentsTypes where id_Type = 35
116   -delete from WaterComponentsTypes where id_Type = 36
117   -delete from WaterComponentsTypes where id_Type = 37
118   -delete from WaterComponentsTypes where id_Type = 38
119   -delete from WaterComponentsTypes where id_Type = 39
120   -delete from WaterComponentsTypes where id_Type = 40
121   -delete from WaterComponentsTypes where id_Type = 41
122   -delete from WaterComponentsTypes where id_Type = 42
123   -delete from WaterComponentsTypes where id_Type = 43
124   -delete from WaterComponentsTypes where id_Type = 44
125   -delete from WaterComponentsTypes where id_Type = 45
126   -delete from WaterComponentsTypes where id_Type = 46
127   -
128   -/* insere parâmetros de todos subtipos */
129   -
130   -CREATE TABLE [dbo].[WaterComponentsSubTypes](
131   - [id_Type] [int] NOT NULL,
132   - [id_SubType] [int] NOT NULL,
133   - [Description_] [varchar](50) NULL,
134   - [Selection_] [bit] NOT NULL,
135   - [Max_] [numeric](18, 4) NULL,
136   - [Min_] [numeric](18, 4) NULL,
137   - [DefaultValue] [nvarchar](50) NOT NULL,
138   - [DataType] [int] NULL,
139   - [EPAREF] [nvarchar](10) NULL
140   -) ON [PRIMARY]
141   -
142   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
143   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
144   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
145   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
146   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
147   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
148   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
149   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
150   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
151   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
152   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
153   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
154   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
155   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
156   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
157   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
158   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
159   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
160   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
161   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
162   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
163   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
164   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
165   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
166   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
167   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
168   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
169   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
170   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
171   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
172   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
173   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
174   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
175   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
176   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
177   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
178   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
179   -
180   -/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
181   -
182   -CREATE TABLE [dbo].[WaterComponentsSelections](
183   - [id_Type] [int] NOT NULL,
184   - [id_SubType] [int] NOT NULL,
185   - [Option_] [varchar](25) NOT NULL,
186   - [Value_] [nvarchar](50) NOT NULL,
187   - [Description_] [varchar](30) NULL
188   -) ON [PRIMARY]
189   -
190   -GO
191   -
192   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
193   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
194   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
195   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
196   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
197   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
198   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
199   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
200   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
201   -
sql/20160210083900-scripts versao GeoSan 7.0.30.sql 0 → 100644
... ... @@ -0,0 +1,102 @@
  1 +USE [ArturNogueira-B]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:40:47 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  23 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  24 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  25 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  26 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  27 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  59 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  60 +/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:40:47 ******/
  61 +SET ANSI_NULLS ON
  62 +GO
  63 +SET QUOTED_IDENTIFIER ON
  64 +GO
  65 +SET ANSI_PADDING ON
  66 +GO
  67 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  68 + [id_Type] [int] NOT NULL,
  69 + [id_SubType] [int] NOT NULL,
  70 + [Description_] [varchar](50) NULL,
  71 + [Selection_] [bit] NOT NULL,
  72 + [Max_] [numeric](18, 4) NULL,
  73 + [Min_] [numeric](18, 4) NULL,
  74 + [DefaultValue] [nvarchar](50) NOT NULL,
  75 + [DataType] [int] NULL,
  76 + [EPAREF] [nvarchar](10) NULL
  77 +) ON [PRIMARY]
  78 +GO
  79 +SET ANSI_PADDING OFF
  80 +GO
  81 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  82 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 129, NULL)
  83 +/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:40:47 ******/
  84 +SET ANSI_NULLS ON
  85 +GO
  86 +SET QUOTED_IDENTIFIER ON
  87 +GO
  88 +SET ANSI_PADDING ON
  89 +GO
  90 +CREATE TABLE [dbo].[WaterComponentsSelections](
  91 + [id_Type] [int] NOT NULL,
  92 + [id_SubType] [int] NOT NULL,
  93 + [Option_] [varchar](25) NOT NULL,
  94 + [Value_] [tinyint] NOT NULL,
  95 + [Description_] [varchar](30) NULL
  96 +) ON [PRIMARY]
  97 +GO
  98 +SET ANSI_PADDING OFF
  99 +GO
  100 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', 1, N'')
  101 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', 0, N'')
  102 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', 2, N'')
... ...
sql/20160210083900-scripts versão GeoSan 7.0.30.sql
... ... @@ -1,102 +0,0 @@
1   -USE [ArturNogueira-B]
2   -GO
3   -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:40:47 ******/
4   -SET ANSI_NULLS ON
5   -GO
6   -SET QUOTED_IDENTIFIER ON
7   -GO
8   -SET ANSI_PADDING ON
9   -GO
10   -CREATE TABLE [dbo].[WaterComponentsTypes](
11   - [id_Type] [int] IDENTITY(1,1) NOT NULL,
12   - [Description_] [varchar](25) NULL,
13   - [Specification_] [varchar](100) NULL
14   -) ON [PRIMARY]
15   -GO
16   -SET ANSI_PADDING OFF
17   -GO
18   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
19   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
20   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
21   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
22   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
23   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
24   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
25   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
26   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
27   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
28   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
29   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
30   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
31   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
32   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
33   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
34   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
35   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
36   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
37   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
38   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
39   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
40   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
41   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
42   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
43   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
44   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
45   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
46   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
47   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
48   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
49   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
50   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
51   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
52   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
53   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
54   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
55   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
56   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
57   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
58   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
59   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
60   -/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:40:47 ******/
61   -SET ANSI_NULLS ON
62   -GO
63   -SET QUOTED_IDENTIFIER ON
64   -GO
65   -SET ANSI_PADDING ON
66   -GO
67   -CREATE TABLE [dbo].[WaterComponentsSubTypes](
68   - [id_Type] [int] NOT NULL,
69   - [id_SubType] [int] NOT NULL,
70   - [Description_] [varchar](50) NULL,
71   - [Selection_] [bit] NOT NULL,
72   - [Max_] [numeric](18, 4) NULL,
73   - [Min_] [numeric](18, 4) NULL,
74   - [DefaultValue] [nvarchar](50) NOT NULL,
75   - [DataType] [int] NULL,
76   - [EPAREF] [nvarchar](10) NULL
77   -) ON [PRIMARY]
78   -GO
79   -SET ANSI_PADDING OFF
80   -GO
81   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
82   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 129, NULL)
83   -/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:40:47 ******/
84   -SET ANSI_NULLS ON
85   -GO
86   -SET QUOTED_IDENTIFIER ON
87   -GO
88   -SET ANSI_PADDING ON
89   -GO
90   -CREATE TABLE [dbo].[WaterComponentsSelections](
91   - [id_Type] [int] NOT NULL,
92   - [id_SubType] [int] NOT NULL,
93   - [Option_] [varchar](25) NOT NULL,
94   - [Value_] [tinyint] NOT NULL,
95   - [Description_] [varchar](30) NULL
96   -) ON [PRIMARY]
97   -GO
98   -SET ANSI_PADDING OFF
99   -GO
100   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', 1, N'')
101   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', 0, N'')
102   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', 2, N'')
sql/20160210084500-scripts completos dos metadados das componentes de agua.sql 0 → 100644
... ... @@ -0,0 +1,147 @@
  1 +USE [ArturNogueira-B-1]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  23 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  24 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  25 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  26 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  27 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  63 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  64 +/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:45:01 ******/
  65 +SET ANSI_NULLS ON
  66 +GO
  67 +SET QUOTED_IDENTIFIER ON
  68 +GO
  69 +SET ANSI_PADDING ON
  70 +GO
  71 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  72 + [id_Type] [int] NOT NULL,
  73 + [id_SubType] [int] NOT NULL,
  74 + [Description_] [varchar](50) NULL,
  75 + [Selection_] [bit] NOT NULL,
  76 + [Max_] [numeric](18, 4) NULL,
  77 + [Min_] [numeric](18, 4) NULL,
  78 + [DefaultValue] [nvarchar](50) NOT NULL,
  79 + [DataType] [int] NULL,
  80 + [EPAREF] [nvarchar](10) NULL
  81 +) ON [PRIMARY]
  82 +GO
  83 +SET ANSI_PADDING OFF
  84 +GO
  85 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  86 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  87 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  88 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  89 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  90 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  91 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  92 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  93 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  94 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  95 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  96 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  97 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  98 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  99 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  100 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  101 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  102 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  103 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  104 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  105 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  106 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  107 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  108 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  109 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  110 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  111 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  112 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  113 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  114 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  115 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  116 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  117 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  118 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  119 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  120 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  121 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  122 +/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:45:01 ******/
  123 +SET ANSI_NULLS ON
  124 +GO
  125 +SET QUOTED_IDENTIFIER ON
  126 +GO
  127 +SET ANSI_PADDING ON
  128 +GO
  129 +CREATE TABLE [dbo].[WaterComponentsSelections](
  130 + [id_Type] [int] NOT NULL,
  131 + [id_SubType] [int] NOT NULL,
  132 + [Option_] [varchar](25) NOT NULL,
  133 + [Value_] [nvarchar](50) NOT NULL,
  134 + [Description_] [varchar](30) NULL
  135 +) ON [PRIMARY]
  136 +GO
  137 +SET ANSI_PADDING OFF
  138 +GO
  139 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  140 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  141 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  142 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  143 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  144 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  145 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  146 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  147 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
... ...
sql/20160210084500-scripts completos dos metadados das componentes de água.sql
... ... @@ -1,147 +0,0 @@
1   -USE [ArturNogueira-B-1]
2   -GO
3   -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
4   -SET ANSI_NULLS ON
5   -GO
6   -SET QUOTED_IDENTIFIER ON
7   -GO
8   -SET ANSI_PADDING ON
9   -GO
10   -CREATE TABLE [dbo].[WaterComponentsTypes](
11   - [id_Type] [int] IDENTITY(1,1) NOT NULL,
12   - [Description_] [varchar](25) NULL,
13   - [Specification_] [varchar](100) NULL
14   -) ON [PRIMARY]
15   -GO
16   -SET ANSI_PADDING OFF
17   -GO
18   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
19   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
20   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
21   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
22   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
23   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
24   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
25   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
26   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
27   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
28   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
29   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
30   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
31   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
32   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
33   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
34   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
35   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
36   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
37   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
38   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
39   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
40   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
41   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
42   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
43   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
44   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
45   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
46   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
47   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
48   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
49   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
50   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
51   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
52   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
53   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
54   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
55   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
56   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
57   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
58   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
59   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
60   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
61   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
62   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
63   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
64   -/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:45:01 ******/
65   -SET ANSI_NULLS ON
66   -GO
67   -SET QUOTED_IDENTIFIER ON
68   -GO
69   -SET ANSI_PADDING ON
70   -GO
71   -CREATE TABLE [dbo].[WaterComponentsSubTypes](
72   - [id_Type] [int] NOT NULL,
73   - [id_SubType] [int] NOT NULL,
74   - [Description_] [varchar](50) NULL,
75   - [Selection_] [bit] NOT NULL,
76   - [Max_] [numeric](18, 4) NULL,
77   - [Min_] [numeric](18, 4) NULL,
78   - [DefaultValue] [nvarchar](50) NOT NULL,
79   - [DataType] [int] NULL,
80   - [EPAREF] [nvarchar](10) NULL
81   -) ON [PRIMARY]
82   -GO
83   -SET ANSI_PADDING OFF
84   -GO
85   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
86   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
87   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
88   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
89   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
90   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
91   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
92   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
93   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
94   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
95   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
96   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
97   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
98   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
99   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
100   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
101   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
102   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
103   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
104   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
105   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
106   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
107   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
108   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
109   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
110   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
111   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
112   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
113   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
114   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
115   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
116   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
117   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
118   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
119   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
120   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
121   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
122   -/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:45:01 ******/
123   -SET ANSI_NULLS ON
124   -GO
125   -SET QUOTED_IDENTIFIER ON
126   -GO
127   -SET ANSI_PADDING ON
128   -GO
129   -CREATE TABLE [dbo].[WaterComponentsSelections](
130   - [id_Type] [int] NOT NULL,
131   - [id_SubType] [int] NOT NULL,
132   - [Option_] [varchar](25) NOT NULL,
133   - [Value_] [nvarchar](50) NOT NULL,
134   - [Description_] [varchar](30) NULL
135   -) ON [PRIMARY]
136   -GO
137   -SET ANSI_PADDING OFF
138   -GO
139   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
140   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
141   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
142   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
143   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
144   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
145   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
146   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
147   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
sql/20160210084600-scripts para atualizar para versao 7.0.44.sql 0 → 100644
... ... @@ -0,0 +1,69 @@
  1 +USE [ArturNogueira-B-1]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON /* rodar esta linha antes de realizar as inserções */
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  23 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  24 +
  25 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  26 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  27 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  28 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  29 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  30 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  31 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  32 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  33 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  34 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  35 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  36 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  37 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  38 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  39 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  40 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  41 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  42 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  43 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  44 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  45 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  46 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  47 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  48 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  49 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  50 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  51 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  52 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  53 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  54 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  55 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  56 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  57 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  58 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  59 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  60 +
  61 +/* Selecione no SQLServer Management Studio: Tools - Options - Designer e então retire a seleção de Prevent saving changes that require the table re-creation */
  62 +ALTER TABLE [dbo].[WaterComponentsSelections] ALTER COLUMN [Value_] [nvarchar](50)
  63 +
  64 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  65 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  66 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  67 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  68 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  69 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
... ...
sql/20160210084600-scripts para atualizar para versão 7.0.44.sql
... ... @@ -1,69 +0,0 @@
1   -USE [ArturNogueira-B-1]
2   -GO
3   -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
4   -SET ANSI_NULLS ON
5   -GO
6   -SET QUOTED_IDENTIFIER ON
7   -GO
8   -SET ANSI_PADDING ON
9   -GO
10   -CREATE TABLE [dbo].[WaterComponentsTypes](
11   - [id_Type] [int] IDENTITY(1,1) NOT NULL,
12   - [Description_] [varchar](25) NULL,
13   - [Specification_] [varchar](100) NULL
14   -) ON [PRIMARY]
15   -GO
16   -SET ANSI_PADDING OFF
17   -GO
18   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON /* rodar esta linha antes de realizar as inserções */
19   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
20   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
21   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
22   -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
23   -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
24   -
25   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
26   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
27   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
28   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
29   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
30   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
31   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
32   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
33   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
34   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
35   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
36   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
37   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
38   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
39   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
40   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
41   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
42   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
43   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
44   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
45   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
46   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
47   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
48   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
49   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
50   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
51   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
52   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
53   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
54   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
55   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
56   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
57   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
58   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
59   -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
60   -
61   -/* Selecione no SQLServer Management Studio: Tools - Options - Designer e então retire a seleção de Prevent saving changes that require the table re-creation */
62   -ALTER TABLE [dbo].[WaterComponentsSelections] ALTER COLUMN [Value_] [nvarchar](50)
63   -
64   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
65   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
66   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
67   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
68   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
69   -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
trunk/Forms/frm1TePrinter - Copia.frm 0 → 100644
... ... @@ -0,0 +1,477 @@
  1 +VERSION 5.00
  2 +Object = "{F141AAE7-BD4C-4793-88DB-10FE8CBA518C}#1.0#0"; "TeComPrinter.dll"
  3 +Object = "{9AB389E7-EAED-4DBF-941D-EB86ED1F9A76}#1.0#0"; "TeComConnection.dll"
  4 +Object = "{EE78E37B-39BE-42FA-80B7-E525529739F7}#1.0#0"; "TeComViewDatabase.dll"
  5 +Object = "{F9043C88-F6F2-101A-A3C9-08002B2F49FB}#1.2#0"; "COMDLG32.OCX"
  6 +Object = "{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0"; "MSCOMCTL.OCX"
  7 +Begin VB.Form frmTePrinter
  8 + Caption = "Módulo de Impressão"
  9 + ClientHeight = 10620
  10 + ClientLeft = 60
  11 + ClientTop = 750
  12 + ClientWidth = 9960
  13 + LinkTopic = "Form1"
  14 + ScaleHeight = 10620
  15 + ScaleWidth = 9960
  16 + StartUpPosition = 1 'CenterOwner
  17 + Begin TeComPrinterLibCtl.TePrinter TePrinter1
  18 + Height = 9375
  19 + Left = 120
  20 + Begin VB.Menu mnArquivo
  21 + Caption = "Arquivo"
  22 + Begin VB.Menu mnConfPagina
  23 + Caption = "Configurar Página"
  24 + End
  25 + Begin VB.Menu mnImprimir
  26 + Caption = "Imprimir"
  27 + End
  28 + Begin VB.Menu mnSep1
  29 + Caption = "-"
  30 + End
  31 + Begin VB.Menu mnFechar
  32 + Caption = "Fechar"
  33 + End
  34 + End
  35 + Begin VB.Menu mnEditar
  36 + Caption = "Editar"
  37 + Begin VB.Menu mnFonte
  38 + Caption = "Fonte"
  39 + Begin VB.Menu mnTamanho
  40 + Caption = "Tamanho"
  41 + Begin VB.Menu mn8
  42 + Caption = "8"
  43 + End
  44 + Begin VB.Menu mn12
  45 + Caption = "12"
  46 + End
  47 + Begin VB.Menu mn16
  48 + Caption = "16"
  49 + End
  50 + Begin VB.Menu mn32
  51 + Caption = "32"
  52 + End
  53 + End
  54 + Begin VB.Menu mnTipo
  55 + Caption = "Tipo"
  56 + Begin VB.Menu mnArial
  57 + Caption = "Arial"
  58 + End
  59 + Begin VB.Menu mnCourrier
  60 + Caption = "Arial Negrito"
  61 + End
  62 + End
  63 + End
  64 + End
  65 + Begin VB.Menu mnInserir
  66 + Caption = "Inserir"
  67 + Begin VB.Menu mnMapa
  68 + Caption = "Mapa"
  69 + End
  70 + Begin VB.Menu mnImagem
  71 + Caption = "Imagem"
  72 + End
  73 + Begin VB.Menu mnTexto
  74 + Caption = "Texto"
  75 + End
  76 + Begin VB.Menu mnLinha
  77 + Caption = "Linha"
  78 + End
  79 + Begin VB.Menu mnRetangulo
  80 + Caption = "Retangulo"
  81 + End
  82 + Begin VB.Menu mnElipse
  83 + Caption = "Elipse"
  84 + End
  85 + Begin VB.Menu mnBarraEscala
  86 + Caption = "Barra de Escala"
  87 + End
  88 + End
  89 + Begin VB.Menu mnAcaoMapa
  90 + Caption = "Mapa"
  91 + Begin VB.Menu mnMover
  92 + Caption = "Mover"
  93 + End
  94 + Begin VB.Menu mnAproximar
  95 + Caption = "Aproximar"
  96 + End
  97 + Begin VB.Menu mnAfastar
  98 + Caption = "Afastar"
  99 + End
  100 + Begin VB.Menu mnEscala
  101 + Caption = "Definir Escala"
  102 + End
  103 + End
  104 +End
  105 +Attribute VB_Name = "frmTePrinter"
  106 +Attribute VB_GlobalNameSpace = False
  107 +Attribute VB_Creatable = False
  108 +Attribute VB_PredeclaredId = True
  109 +Attribute VB_Exposed = False
  110 +Dim ObjName As String
  111 +Dim contador As Integer
  112 +Dim mPROVEDOR As String
  113 +Dim mSERVIDOR As String
  114 +Dim mPORTA As String
  115 +Dim mBANCO As String
  116 +Dim mUSUARIO As String
  117 +Dim Senha As String
  118 +Dim decriptada As String
  119 +Dim username As String
  120 +
  121 +
  122 +
  123 +Private Sub mnEscala_Click()
  124 +On Error GoTo saida
  125 + Dim Scala As Double
  126 +
  127 +
  128 + If CStr(ObjName) <> "" Then
  129 +
  130 + Scala = InputBox("", "Informe a escala do mapa")
  131 +
  132 + If Scala > 0 Then
  133 + TePrinter1.setObjectPropertyValueByName ObjName, "MapScale_Property", CDbl(Scala)
  134 + TePrinter1.execute
  135 +
  136 + End If
  137 + Else
  138 +
  139 + MsgBox "Selecione o mapa antes de definir a escala.", vbInformation, ""
  140 +
  141 + End If
  142 +saida:
  143 +
  144 +End Sub
  145 +
  146 +Private Function MudaFonte(Tam As Double)
  147 +On Error GoTo saida
  148 +Dim tamTexto As String
  149 +
  150 + 'retorna todos os nomes de propriedades
  151 + 'tamTexto = TePrinter1.getLayoutObjectPropertyName(ObjName, 5)
  152 +
  153 + TePrinter1.setObjectPropertyValue ObjName, 6, Tam
  154 + TePrinter1.execute
  155 +
  156 +
  157 +saida:
  158 +
  159 +End Function
  160 +
  161 +Private Function MudaTipoFonte(tipo As String)
  162 +On Error GoTo saida
  163 +
  164 + 'ObjName = Me.TePrinter1.getLayoutObjectPropertyValue("Text_2", 7) 'fonte
  165 +
  166 + TePrinter1.setObjectPropertyValue ObjName, 7, tipo
  167 + TePrinter1.execute
  168 +
  169 +saida:
  170 +End Function
  171 +
  172 +Public Function id_objeto()
  173 +Dim qtd As Integer
  174 +
  175 + 'VERIFICA SE ALGO SELECIONADO
  176 + qtd = Me.TePrinter1.getLayoutSelectObjectCount
  177 + If qtd > 0 Then
  178 +
  179 + 'PASSA PARA O ObjName O NOME DO OBJETO SELECIONADO
  180 + ObjName = Me.TePrinter1.getLayoutSelectObjectName(0)
  181 +
  182 + End If
  183 +
  184 +
  185 +
  186 +End Function
  187 +
  188 +
  189 +Private Sub cmdSetScale_Click()
  190 + Dim Texto As String
  191 + Texto = InputBox("Informe o texto:")
  192 +
  193 + If Trim(Texto) <> "" Then
  194 + TePrinter1.addText Texto
  195 + End If
  196 +
  197 + TePrinter1.setObjectPropertyValueByName strObjSelecionado, "MapScale_Property", CDbl(txtScala.Text)
  198 + TePrinter1.execute
  199 +End Sub
  200 +
  201 +
  202 +Private Sub Form_Load()
  203 +
  204 + TePrinter1.Provider = frmCanvas.TipoConexao
  205 +
  206 +If (frmCanvas.TipoConexao = 4) Then
  207 +
  208 +If (contador <> 10) Then
  209 +
  210 +mSERVIDOR = ReadINI("CONEXAO", "SERVIDOR", App.path & "\CONTROLES\GEOSAN.ini")
  211 +mPORTA = ReadINI("CONEXAO", "PORTA", App.path & "\CONTROLES\GEOSAN.ini")
  212 +mBANCO = ReadINI("CONEXAO", "BANCO", App.path & "\CONTROLES\GEOSAN.ini")
  213 +mUSUARIO = ReadINI("CONEXAO", "USUARIO", App.path & "\CONTROLES\GEOSAN.ini")
  214 +Senha = ReadINI("CONEXAO", "SENHA", App.path & "\CONTROLES\GEOSAN.ini")
  215 +username = ReadINI("CONEXAO", "USER", App.path & "\CONTROLES\GEOSAN.ini")
  216 +frmCanvas.FunDecripta (Senha)
  217 +decriptada = frmCanvas.Senha
  218 +
  219 +TeAcXConnection1.Open mUSUARIO, decriptada, mBANCO, mSERVIDOR, mPORTA
  220 +contador = 10
  221 +
  222 +Else
  223 +
  224 +TePrinter1.Provider = frmCanvas.TipoConexao
  225 +'TePrinter1.connection = TeAcXConnection1.objectConnection_
  226 +
  227 +End If
  228 +
  229 +Else
  230 +TePrinter1.Provider = frmCanvas.TipoConexao
  231 +TePrinter1.connection = Conn
  232 +
  233 +End If
  234 +
  235 +TePrinter1.execute
  236 +
  237 +End Sub
  238 +
  239 +Private Sub Form_Resize()
  240 +On Error GoTo Trata_Erro
  241 +
  242 +TePrinter1.Width = 9960
  243 +TePrinter1.Height = Me.Height - 1250 '- tbMain.Height
  244 +
  245 +Trata_Erro:
  246 +
  247 +If Err.Number = 0 Or Err.Number = 20 Then
  248 + Resume Next
  249 +Else
  250 + Exit Sub
  251 +End If
  252 +
  253 +End Sub
  254 +
  255 +Private Sub mn8_Click()
  256 + MudaFonte 8
  257 +End Sub
  258 +
  259 +Private Sub mn12_Click()
  260 +
  261 +
  262 + TePrinter1.setObjectPropertyValue ObjName, 6, 12 'CLng(tamanho)
  263 + TePrinter1.execute
  264 +
  265 +End Sub
  266 +
  267 +Private Sub mn16_Click()
  268 + MudaFonte 16
  269 +End Sub
  270 +
  271 +Private Sub mn32_Click()
  272 + MudaFonte 32
  273 +End Sub
  274 +
  275 +
  276 +
  277 +Private Sub mnAfastar_Click()
  278 + TePrinter1.setMapMode zoomOut
  279 +End Sub
  280 +
  281 +Private Sub mnAproximar_Click()
  282 + TePrinter1.setMapMode zoomIn
  283 +End Sub
  284 +
  285 +Private Sub mnArial_Click()
  286 + MudaTipoFonte "Arial"
  287 +End Sub
  288 +
  289 +Private Sub mnCourrier_Click()
  290 + MudaTipoFonte "Arial Black"
  291 +End Sub
  292 +
  293 +Private Sub mnLucConsole_Click()
  294 + MudaTipoFonte "Lucida Console"
  295 +End Sub
  296 +
  297 +Private Sub mnConfPagina_Click()
  298 + If TePrinter1.orientation = portrait Then
  299 + frmPageSetup.setOrientation True
  300 + Else
  301 + frmPageSetup.setOrientation False
  302 + End If
  303 +
  304 + frmPageSetup.setPageSize TePrinter1.PaperSize
  305 +
  306 + frmPageSetup.Show 1, Me
  307 + If frmPageSetup.getOK = True Then
  308 + If frmPageSetup.getOrientation = True Then
  309 + TePrinter1.orientation = portrait
  310 + Else
  311 + TePrinter1.orientation = landscape
  312 + End If
  313 + TePrinter1.PaperSize = frmPageSetup.getPageSize
  314 +
  315 + TePrinter1.execute
  316 + End If
  317 +End Sub
  318 +
  319 +
  320 +
  321 +
  322 +
  323 +
  324 +
  325 +Private Sub mnImagem_Click()
  326 + cmmOpen.ShowOpen
  327 + TePrinter1.addImage cmmOpen.FileName
  328 +End Sub
  329 +
  330 +Private Sub mnImprimir_Click()
  331 +
  332 + TePrinter1.printExecute ("Teste")
  333 +
  334 +End Sub
  335 +
  336 +Private Sub mnLinha_Click()
  337 +
  338 + TePrinter1.addLine
  339 +
  340 +End Sub
  341 +
  342 +
  343 +
  344 +Private Sub mnMover_Click()
  345 + TePrinter1.setMapMode pan
  346 +End Sub
  347 +
  348 +Private Sub mnBarraEscala_Click()
  349 + TePrinter1.addScale
  350 +End Sub
  351 +
  352 +
  353 +
  354 +
  355 +Private Sub mnMapa_Click()
  356 +
  357 + 'COLETA AS VARIÁVEIS GLOBAIS PARA O MÓDULO DE IMPRESSÃO PASSADAS NO END PLOT VIEW
  358 + 'CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  359 +
  360 + 'ADICIONA O MAPA QUE ESTAVA NA TELA DO GEOSAN
  361 + 'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  362 +
  363 +If (frmCanvas.TipoConexao = 4) Then
  364 +
  365 +'TePrinter1.provider = TeComPrinterLib.CONNECTION_TYPE.PostgreSQL;
  366 +TePrinter1.addDatabase
  367 +TePrinter1.execute
  368 +'TePrinter1.Open ("nexussql.gpl")
  369 +'TePrinter1.execute
  370 +
  371 +
  372 +
  373 +TePrinter1.setObjectPropertyValueByName "Database_1", "left_Property", "15.0"
  374 +TePrinter1.execute
  375 +TePrinter1.setObjectPropertyValueByName "Database_1", "top_Property", "20.0"
  376 +TePrinter1.execute
  377 +TePrinter1.setObjectPropertyValueByName "Database_1", "width_Property", "11.0"
  378 +TePrinter1.execute
  379 +TePrinter1.setObjectPropertyValueByName "Database_1", "height_Property", "11.0"
  380 +TePrinter1.execute
  381 +TePrinter1.setObjectPropertyValueByName "Database_1", "angle_Property", "0.0"
  382 +TePrinter1.execute
  383 +
  384 +TePrinter1.setObjectPropertyValueByName "Database_1", "username_Property", "postgres"
  385 +TePrinter1.execute
  386 +TePrinter1.setObjectPropertyValueByName "Database_1", "password_Property", "gustavo"
  387 +TePrinter1.execute
  388 +TePrinter1.setObjectPropertyValueByName "Database_1", "host_Property", "localhost"
  389 +TePrinter1.execute
  390 +TePrinter1.setObjectPropertyValueByName "Database_1", "databasename_Property", "teste"
  391 +TePrinter1.execute
  392 +TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
  393 +TePrinter1.execute
  394 +TePrinter1.setObjectPropertyValueByName "Database_1", "databasetype_Property", "2.0"
  395 +TePrinter1.execute
  396 +
  397 +
  398 +
  399 +TePrinter1.setObjectPropertyValueByName "Map_3", "viewname_Property", "Administrador"
  400 +TePrinter1.execute
  401 +TePrinter1.setObjectPropertyValueByName "Map_3", "viewuser_Property", "Administrador"
  402 +TePrinter1.execute
  403 +TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
  404 +TePrinter1.execute
  405 +
  406 +TePrinter1.setObjectPropertyValueByName "Map_3", "left_Property", "15.0"
  407 +TePrinter1.execute
  408 +TePrinter1.setObjectPropertyValueByName "Map_3", "top_Property", "44.0"
  409 +TePrinter1.execute
  410 +TePrinter1.setObjectPropertyValueByName "Map_3", "width_Property", "300.0"
  411 +TePrinter1.execute
  412 +TePrinter1.setObjectPropertyValueByName "Map_3", "height_Property", "200.0"
  413 +TePrinter1.execute
  414 +TePrinter1.setObjectPropertyValueByName "Map_3", "angle_Property", "0.0"
  415 +TePrinter1.execute
  416 +
  417 +TePrinter1.setObjectPropertyValueByName "Map_3", "mapscale_Property", "2200000"
  418 +TePrinter1.execute
  419 +
  420 +TePrinter1.setObjectPropertyValueByName "Map_3", "fixedscale_Property", "False"
  421 +TePrinter1.execute
  422 +
  423 +
  424 +
  425 +
  426 +'TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
  427 +'TePrinter1.execute
  428 +
  429 +
  430 +'TePrinter1.addDatabase
  431 +
  432 +'TePrinter1.execute
  433 +'TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
  434 +
  435 +
  436 +
  437 +
  438 +End If
  439 +
  440 +'update te_layer set lower_x = 715603;
  441 +'update te_layer set lower_y = 7702100;
  442 +'update te_layer set upper_x = 722075;
  443 +'update te_layer set upper_y = 7711330;
  444 +TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  445 +'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  446 +
  447 +End Sub
  448 +
  449 +Private Sub mnRetangulo_Click()
  450 + TePrinter1.addRectangle
  451 +End Sub
  452 +
  453 +Private Sub mnElipse_Click()
  454 + TePrinter1.addEllipse
  455 +End Sub
  456 +
  457 +Private Sub mnTexto_Click()
  458 + Dim Texto As String
  459 + Texto = InputBox("Informe o texto:")
  460 +
  461 + If Trim(Texto) <> "" Then
  462 + TePrinter1.addText Texto
  463 + End If
  464 +
  465 +End Sub
  466 +
  467 +
  468 +Private Sub TePrinter1_endProcess(ByVal partial As Boolean)
  469 +
  470 + DoEvents
  471 + If (partial = False) Then
  472 + 'mnProperties_Click
  473 + id_objeto
  474 + End If
  475 +End Sub
  476 +
  477 +
... ...
trunk/Forms/frm1TePrinter - Cópia.frm
... ... @@ -1,477 +0,0 @@
1   -VERSION 5.00
2   -Object = "{F141AAE7-BD4C-4793-88DB-10FE8CBA518C}#1.0#0"; "TeComPrinter.dll"
3   -Object = "{9AB389E7-EAED-4DBF-941D-EB86ED1F9A76}#1.0#0"; "TeComConnection.dll"
4   -Object = "{EE78E37B-39BE-42FA-80B7-E525529739F7}#1.0#0"; "TeComViewDatabase.dll"
5   -Object = "{F9043C88-F6F2-101A-A3C9-08002B2F49FB}#1.2#0"; "COMDLG32.OCX"
6   -Object = "{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0"; "MSCOMCTL.OCX"
7   -Begin VB.Form frmTePrinter
8   - Caption = "Módulo de Impressão"
9   - ClientHeight = 10620
10   - ClientLeft = 60
11   - ClientTop = 750
12   - ClientWidth = 9960
13   - LinkTopic = "Form1"
14   - ScaleHeight = 10620
15   - ScaleWidth = 9960
16   - StartUpPosition = 1 'CenterOwner
17   - Begin TeComPrinterLibCtl.TePrinter TePrinter1
18   - Height = 9375
19   - Left = 120
20   - Begin VB.Menu mnArquivo
21   - Caption = "Arquivo"
22   - Begin VB.Menu mnConfPagina
23   - Caption = "Configurar Página"
24   - End
25   - Begin VB.Menu mnImprimir
26   - Caption = "Imprimir"
27   - End
28   - Begin VB.Menu mnSep1
29   - Caption = "-"
30   - End
31   - Begin VB.Menu mnFechar
32   - Caption = "Fechar"
33   - End
34   - End
35   - Begin VB.Menu mnEditar
36   - Caption = "Editar"
37   - Begin VB.Menu mnFonte
38   - Caption = "Fonte"
39   - Begin VB.Menu mnTamanho
40   - Caption = "Tamanho"
41   - Begin VB.Menu mn8
42   - Caption = "8"
43   - End
44   - Begin VB.Menu mn12
45   - Caption = "12"
46   - End
47   - Begin VB.Menu mn16
48   - Caption = "16"
49   - End
50   - Begin VB.Menu mn32
51   - Caption = "32"
52   - End
53   - End
54   - Begin VB.Menu mnTipo
55   - Caption = "Tipo"
56   - Begin VB.Menu mnArial
57   - Caption = "Arial"
58   - End
59   - Begin VB.Menu mnCourrier
60   - Caption = "Arial Negrito"
61   - End
62   - End
63   - End
64   - End
65   - Begin VB.Menu mnInserir
66   - Caption = "Inserir"
67   - Begin VB.Menu mnMapa
68   - Caption = "Mapa"
69   - End
70   - Begin VB.Menu mnImagem
71   - Caption = "Imagem"
72   - End
73   - Begin VB.Menu mnTexto
74   - Caption = "Texto"
75   - End
76   - Begin VB.Menu mnLinha
77   - Caption = "Linha"
78   - End
79   - Begin VB.Menu mnRetangulo
80   - Caption = "Retangulo"
81   - End
82   - Begin VB.Menu mnElipse
83   - Caption = "Elipse"
84   - End
85   - Begin VB.Menu mnBarraEscala
86   - Caption = "Barra de Escala"
87   - End
88   - End
89   - Begin VB.Menu mnAcaoMapa
90   - Caption = "Mapa"
91   - Begin VB.Menu mnMover
92   - Caption = "Mover"
93   - End
94   - Begin VB.Menu mnAproximar
95   - Caption = "Aproximar"
96   - End
97   - Begin VB.Menu mnAfastar
98   - Caption = "Afastar"
99   - End
100   - Begin VB.Menu mnEscala
101   - Caption = "Definir Escala"
102   - End
103   - End
104   -End
105   -Attribute VB_Name = "frmTePrinter"
106   -Attribute VB_GlobalNameSpace = False
107   -Attribute VB_Creatable = False
108   -Attribute VB_PredeclaredId = True
109   -Attribute VB_Exposed = False
110   -Dim ObjName As String
111   -Dim contador As Integer
112   -Dim mPROVEDOR As String
113   -Dim mSERVIDOR As String
114   -Dim mPORTA As String
115   -Dim mBANCO As String
116   -Dim mUSUARIO As String
117   -Dim Senha As String
118   -Dim decriptada As String
119   -Dim username As String
120   -
121   -
122   -
123   -Private Sub mnEscala_Click()
124   -On Error GoTo saida
125   - Dim Scala As Double
126   -
127   -
128   - If CStr(ObjName) <> "" Then
129   -
130   - Scala = InputBox("", "Informe a escala do mapa")
131   -
132   - If Scala > 0 Then
133   - TePrinter1.setObjectPropertyValueByName ObjName, "MapScale_Property", CDbl(Scala)
134   - TePrinter1.execute
135   -
136   - End If
137   - Else
138   -
139   - MsgBox "Selecione o mapa antes de definir a escala.", vbInformation, ""
140   -
141   - End If
142   -saida:
143   -
144   -End Sub
145   -
146   -Private Function MudaFonte(Tam As Double)
147   -On Error GoTo saida
148   -Dim tamTexto As String
149   -
150   - 'retorna todos os nomes de propriedades
151   - 'tamTexto = TePrinter1.getLayoutObjectPropertyName(ObjName, 5)
152   -
153   - TePrinter1.setObjectPropertyValue ObjName, 6, Tam
154   - TePrinter1.execute
155   -
156   -
157   -saida:
158   -
159   -End Function
160   -
161   -Private Function MudaTipoFonte(tipo As String)
162   -On Error GoTo saida
163   -
164   - 'ObjName = Me.TePrinter1.getLayoutObjectPropertyValue("Text_2", 7) 'fonte
165   -
166   - TePrinter1.setObjectPropertyValue ObjName, 7, tipo
167   - TePrinter1.execute
168   -
169   -saida:
170   -End Function
171   -
172   -Public Function id_objeto()
173   -Dim qtd As Integer
174   -
175   - 'VERIFICA SE ALGO SELECIONADO
176   - qtd = Me.TePrinter1.getLayoutSelectObjectCount
177   - If qtd > 0 Then
178   -
179   - 'PASSA PARA O ObjName O NOME DO OBJETO SELECIONADO
180   - ObjName = Me.TePrinter1.getLayoutSelectObjectName(0)
181   -
182   - End If
183   -
184   -
185   -
186   -End Function
187   -
188   -
189   -Private Sub cmdSetScale_Click()
190   - Dim Texto As String
191   - Texto = InputBox("Informe o texto:")
192   -
193   - If Trim(Texto) <> "" Then
194   - TePrinter1.addText Texto
195   - End If
196   -
197   - TePrinter1.setObjectPropertyValueByName strObjSelecionado, "MapScale_Property", CDbl(txtScala.Text)
198   - TePrinter1.execute
199   -End Sub
200   -
201   -
202   -Private Sub Form_Load()
203   -
204   - TePrinter1.Provider = frmCanvas.TipoConexao
205   -
206   -If (frmCanvas.TipoConexao = 4) Then
207   -
208   -If (contador <> 10) Then
209   -
210   -mSERVIDOR = ReadINI("CONEXAO", "SERVIDOR", App.path & "\CONTROLES\GEOSAN.ini")
211   -mPORTA = ReadINI("CONEXAO", "PORTA", App.path & "\CONTROLES\GEOSAN.ini")
212   -mBANCO = ReadINI("CONEXAO", "BANCO", App.path & "\CONTROLES\GEOSAN.ini")
213   -mUSUARIO = ReadINI("CONEXAO", "USUARIO", App.path & "\CONTROLES\GEOSAN.ini")
214   -Senha = ReadINI("CONEXAO", "SENHA", App.path & "\CONTROLES\GEOSAN.ini")
215   -username = ReadINI("CONEXAO", "USER", App.path & "\CONTROLES\GEOSAN.ini")
216   -frmCanvas.FunDecripta (Senha)
217   -decriptada = frmCanvas.Senha
218   -
219   -TeAcXConnection1.Open mUSUARIO, decriptada, mBANCO, mSERVIDOR, mPORTA
220   -contador = 10
221   -
222   -Else
223   -
224   -TePrinter1.Provider = frmCanvas.TipoConexao
225   -'TePrinter1.connection = TeAcXConnection1.objectConnection_
226   -
227   -End If
228   -
229   -Else
230   -TePrinter1.Provider = frmCanvas.TipoConexao
231   -TePrinter1.connection = Conn
232   -
233   -End If
234   -
235   -TePrinter1.execute
236   -
237   -End Sub
238   -
239   -Private Sub Form_Resize()
240   -On Error GoTo Trata_Erro
241   -
242   -TePrinter1.Width = 9960
243   -TePrinter1.Height = Me.Height - 1250 '- tbMain.Height
244   -
245   -Trata_Erro:
246   -
247   -If Err.Number = 0 Or Err.Number = 20 Then
248   - Resume Next
249   -Else
250   - Exit Sub
251   -End If
252   -
253   -End Sub
254   -
255   -Private Sub mn8_Click()
256   - MudaFonte 8
257   -End Sub
258   -
259   -Private Sub mn12_Click()
260   -
261   -
262   - TePrinter1.setObjectPropertyValue ObjName, 6, 12 'CLng(tamanho)
263   - TePrinter1.execute
264   -
265   -End Sub
266   -
267   -Private Sub mn16_Click()
268   - MudaFonte 16
269   -End Sub
270   -
271   -Private Sub mn32_Click()
272   - MudaFonte 32
273   -End Sub
274   -
275   -
276   -
277   -Private Sub mnAfastar_Click()
278   - TePrinter1.setMapMode zoomOut
279   -End Sub
280   -
281   -Private Sub mnAproximar_Click()
282   - TePrinter1.setMapMode zoomIn
283   -End Sub
284   -
285   -Private Sub mnArial_Click()
286   - MudaTipoFonte "Arial"
287   -End Sub
288   -
289   -Private Sub mnCourrier_Click()
290   - MudaTipoFonte "Arial Black"
291   -End Sub
292   -
293   -Private Sub mnLucConsole_Click()
294   - MudaTipoFonte "Lucida Console"
295   -End Sub
296   -
297   -Private Sub mnConfPagina_Click()
298   - If TePrinter1.orientation = portrait Then
299   - frmPageSetup.setOrientation True
300   - Else
301   - frmPageSetup.setOrientation False
302   - End If
303   -
304   - frmPageSetup.setPageSize TePrinter1.PaperSize
305   -
306   - frmPageSetup.Show 1, Me
307   - If frmPageSetup.getOK = True Then
308   - If frmPageSetup.getOrientation = True Then
309   - TePrinter1.orientation = portrait
310   - Else
311   - TePrinter1.orientation = landscape
312   - End If
313   - TePrinter1.PaperSize = frmPageSetup.getPageSize
314   -
315   - TePrinter1.execute
316   - End If
317   -End Sub
318   -
319   -
320   -
321   -
322   -
323   -
324   -
325   -Private Sub mnImagem_Click()
326   - cmmOpen.ShowOpen
327   - TePrinter1.addImage cmmOpen.FileName
328   -End Sub
329   -
330   -Private Sub mnImprimir_Click()
331   -
332   - TePrinter1.printExecute ("Teste")
333   -
334   -End Sub
335   -
336   -Private Sub mnLinha_Click()
337   -
338   - TePrinter1.addLine
339   -
340   -End Sub
341   -
342   -
343   -
344   -Private Sub mnMover_Click()
345   - TePrinter1.setMapMode pan
346   -End Sub
347   -
348   -Private Sub mnBarraEscala_Click()
349   - TePrinter1.addScale
350   -End Sub
351   -
352   -
353   -
354   -
355   -Private Sub mnMapa_Click()
356   -
357   - 'COLETA AS VARIÁVEIS GLOBAIS PARA O MÓDULO DE IMPRESSÃO PASSADAS NO END PLOT VIEW
358   - 'CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
359   -
360   - 'ADICIONA O MAPA QUE ESTAVA NA TELA DO GEOSAN
361   - 'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
362   -
363   -If (frmCanvas.TipoConexao = 4) Then
364   -
365   -'TePrinter1.provider = TeComPrinterLib.CONNECTION_TYPE.PostgreSQL;
366   -TePrinter1.addDatabase
367   -TePrinter1.execute
368   -'TePrinter1.Open ("nexussql.gpl")
369   -'TePrinter1.execute
370   -
371   -
372   -
373   -TePrinter1.setObjectPropertyValueByName "Database_1", "left_Property", "15.0"
374   -TePrinter1.execute
375   -TePrinter1.setObjectPropertyValueByName "Database_1", "top_Property", "20.0"
376   -TePrinter1.execute
377   -TePrinter1.setObjectPropertyValueByName "Database_1", "width_Property", "11.0"
378   -TePrinter1.execute
379   -TePrinter1.setObjectPropertyValueByName "Database_1", "height_Property", "11.0"
380   -TePrinter1.execute
381   -TePrinter1.setObjectPropertyValueByName "Database_1", "angle_Property", "0.0"
382   -TePrinter1.execute
383   -
384   -TePrinter1.setObjectPropertyValueByName "Database_1", "username_Property", "postgres"
385   -TePrinter1.execute
386   -TePrinter1.setObjectPropertyValueByName "Database_1", "password_Property", "gustavo"
387   -TePrinter1.execute
388   -TePrinter1.setObjectPropertyValueByName "Database_1", "host_Property", "localhost"
389   -TePrinter1.execute
390   -TePrinter1.setObjectPropertyValueByName "Database_1", "databasename_Property", "teste"
391   -TePrinter1.execute
392   -TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
393   -TePrinter1.execute
394   -TePrinter1.setObjectPropertyValueByName "Database_1", "databasetype_Property", "2.0"
395   -TePrinter1.execute
396   -
397   -
398   -
399   -TePrinter1.setObjectPropertyValueByName "Map_3", "viewname_Property", "Administrador"
400   -TePrinter1.execute
401   -TePrinter1.setObjectPropertyValueByName "Map_3", "viewuser_Property", "Administrador"
402   -TePrinter1.execute
403   -TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
404   -TePrinter1.execute
405   -
406   -TePrinter1.setObjectPropertyValueByName "Map_3", "left_Property", "15.0"
407   -TePrinter1.execute
408   -TePrinter1.setObjectPropertyValueByName "Map_3", "top_Property", "44.0"
409   -TePrinter1.execute
410   -TePrinter1.setObjectPropertyValueByName "Map_3", "width_Property", "300.0"
411   -TePrinter1.execute
412   -TePrinter1.setObjectPropertyValueByName "Map_3", "height_Property", "200.0"
413   -TePrinter1.execute
414   -TePrinter1.setObjectPropertyValueByName "Map_3", "angle_Property", "0.0"
415   -TePrinter1.execute
416   -
417   -TePrinter1.setObjectPropertyValueByName "Map_3", "mapscale_Property", "2200000"
418   -TePrinter1.execute
419   -
420   -TePrinter1.setObjectPropertyValueByName "Map_3", "fixedscale_Property", "False"
421   -TePrinter1.execute
422   -
423   -
424   -
425   -
426   -'TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
427   -'TePrinter1.execute
428   -
429   -
430   -'TePrinter1.addDatabase
431   -
432   -'TePrinter1.execute
433   -'TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
434   -
435   -
436   -
437   -
438   -End If
439   -
440   -'update te_layer set lower_x = 715603;
441   -'update te_layer set lower_y = 7702100;
442   -'update te_layer set upper_x = 722075;
443   -'update te_layer set upper_y = 7711330;
444   -TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
445   -'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
446   -
447   -End Sub
448   -
449   -Private Sub mnRetangulo_Click()
450   - TePrinter1.addRectangle
451   -End Sub
452   -
453   -Private Sub mnElipse_Click()
454   - TePrinter1.addEllipse
455   -End Sub
456   -
457   -Private Sub mnTexto_Click()
458   - Dim Texto As String
459   - Texto = InputBox("Informe o texto:")
460   -
461   - If Trim(Texto) <> "" Then
462   - TePrinter1.addText Texto
463   - End If
464   -
465   -End Sub
466   -
467   -
468   -Private Sub TePrinter1_endProcess(ByVal partial As Boolean)
469   -
470   - DoEvents
471   - If (partial = False) Then
472   - 'mnProperties_Click
473   - id_objeto
474   - End If
475   -End Sub
476   -
477   -